USER’S MANUAL Revision 1.0c X9DRG-HF X9DRG-HTF
1-2 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual Motherboard Image Note: All graphics shown in this manual were based upon the latest P
4-30 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualDelete Boot OptionThis feature allows the user to select a EFI boot device to delete fro
Chapter 4: AMI BIOS4-314-8 Save & ExitThis submenu allows the user to congure the Save and Exit settings for the system.Discard Ch
4-32 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualDiscard ChangesSelect this feature and press <Enter> to discard all the changes and
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each syst
A-2 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualNotes
Appendix B: Software Installation InstructionsB-1Driver/Tool Installation Display ScreenNote 1: Click the icons showing a hand writing on the paper to
B-2 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualSuperDoctor® III Interface Display Screen-I (Health Information)B-2 ConguringSuperDoct
Appendix B: Software Installation InstructionsB-3SuperDoctor® III Interface Display Screen-II (Remote Control)Note: The SDIII utility and the user gu
B-4 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualNotes
(Disclaimer Continued)The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear fa
Chapter 1: Overview1-3Motherboard LayoutNote 1: For the latest CPU/Memory updates, please refer to our Website at http://www.supermicro.com/products/m
1-4 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual Notes: •See Chapter 3 for detailed information on jumpers, I/O ports and JF1 front panel
Chapter 1: Overview1-5X9DRG-HF/X9DRG-HTF JumpersJumperDescription Default SettingJBT1 Clear CMOS See Chapter 2JPB1 BMC Enabled Pins 1-2 (Enabled)JPG1
1-6 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualLED Description State StatusDM1 BMC Heartbeat LED Green BMC NormalLE1 Standby PWR LED Gree
Chapter 1: Overview1-7Motherboard FeaturesCPU• Dual Intel® E5-2600(v2) Series Processors (Socket R LGA 2011); each processor supports four full-width
1-8 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualI/O DevicesSATA Connections • SATA Ports Two (2): SATA 3.0 Ports (I-SATA1~I-SATA2)Four (4
Chapter 1: Overview1-9Fan Control• Fan status monitoring with rmware thermal man-agement via IPMI interface• Low noise fan speed controlSyste
1-10 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualSystem Block DiagramNote: This is a general block diagram and may not exactly represent t
Chapter 1: Overview1-111-2 Processor and Chipset OverviewBuilt upon the functionality and the capability of Intel E5-2600(v2) Series Proces-sors (So
Manual Revision: 1.0cRelease Date: November 15, 2013Unless you request and receive written permission from Super Micro Computer, Inc., you may not cop
1-12 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual1-3 Special FeaturesRecovery from AC Power LossThe Basic I/O System (BIOS) provides a s
Chapter 1: Overview1-131-5 ACPI FeaturesACPI stands for Advanced Conguration and Power Interface. The ACPI specica-tion denes a exible and
1-14 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualThe Super I/O provides functions that comply with ACPI (Advanced Conguration and Power I
Chapter 1: Overview1-15control Super IO functions. The WPCM450R Controller is connected to the network via an external Ethernet PHY module or shared N
1-16 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual•Provides Network Management Security via remote access/console redirection. •Supports
Chapter 2: Installation2-1Chapter 2 Installation2-1 Standardized Warning StatementsThe following statements are industry-standard warnings, provided
2-2 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualAttention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la
Chapter 2: Installation2-3Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations
2-4 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual2-2 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com pone
Chapter 2: Installation2-5OPEN 1stWARNING!2-3 Processor and Heatsink InstallationWarning: When handling the processor package, avoid placing direct p
PrefaceThis manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installation and use
2-6 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualGently push down to pop the load plate open.2. Press the second load lever labeled '
Chapter 2: Installation2-72. Using your thumb and the index nger, remove the 'WARNING' plastic cap from the socket.3. Use your thumb and
2-8 X9DRG-HF/X9DRG-HTF Motherboard User’s Manualvertically. Do not rub the CPU against the surface or against any pins of the socket to a
Chapter 2: Installation2-9Installing a Passive CPU Heatsink1. Apply the proper amount of thermal grease to the heatsink.2. Place the heatsink on top
2-10 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be removed
Chapter 2: Installation2-11JPCIE6JSD1X9DRG-HFLE4SW1JPW10JLAN2JLAN1JRK1JI2C2JI2C1JOH1JSPK1JL1JBT1J21JCOM1JPCIE1JPCIE2JPCIE3JPCIE4JPCIE5JPW11JPW3JPW4JPW
2-12 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualMemory Support for the X9DRG-HF/X9DRG-HTF MotherboardThe X9DRG-HF/X9DRG-HTF motherboard s
Chapter 2: Installation2-13Populating UDIMM (ECC/Non-ECC) Memory ModulesIntel E5-2600(v2) Series Processor UDIMM Memory SupportRanks Per DIMM & Da
2-14 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualPopulating UDIMM (ECC/Non-ECC) Memory ModulesIntel E5-2600 Series Processor UDIMM Memory
Chapter 2: Installation2-15Populating LRDIMM (ECC) Memory ModulesIntel E5-2600(v2) Series Processor LRDIMM Memory SupportRanks Per DIMM & Data Wid
ivConventions Used in the ManualPay special attention to the following symbols for proper system installation and to prevent damage to the system or i
2-16 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualJPCIE6JSD1X9DRG-HFLE4SW1JPW10JLAN2JLAN1JRK1JI2C2JI2C1JOH1JSPK1JL1JBT1J21JCOM1JPCIE1JPCIE2
Chapter 2: Installation2-17Installing the Motherboard1. Install the I/O shield into the chassis. 2. Locate the mounting holes on the motherboard. 3.
2-18 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualJPCIE6JSD1X9DRG-HFLE4SW1JPW10JLAN2JLAN1JRK1JI2C2JI2C1JOH1JSPK1JL1JBT1J21JCOM1JPCIE1JPCIE2
Chapter 2: Installation2-19JPCIE6JSD1X9DRG-HFLE4SW1JPW10JLAN2JLAN1JRK1JI2C2JI2C1JOH1JSPK1JL1JBT1J21JCOM1JPCIE1JPCIE2JPCIE3JPCIE4JPCIE5JPW11JPW3JPW4JPW
2-20 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual1. GLAN1 (X9DRG-HF), TLAN1 (X9DRG-HTF) 2. GLAN2 (X9DRG-HF), TLAN2 (X9DRG-HTF) 3. IPMI_LAN
Chapter 2: Installation2-21JPCIE6JSD1X9DRG-HFLE4SW1JPW10JLAN2JLAN1JRK1JI2C2JI2C1JOH1JSPK1JL1JBT1J21JCOM1JPCIE1JPCIE2JPCIE3JPCIE4JPCIE5JPW11JPW3JPW4JPW
2-22 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualPower ButtonBlue+ (OH/Fan Fail/PWR FaiL/UID LED)1NIC1 Link LEDReset Button2Power Fail LED
Chapter 2: Installation2-23Power ButtonBlue+ (OH/Fan Fail/PWR FaiL/UID LED)1NIC1 Link LEDReset Button2Power Fail LEDHDD LEDFP PWRLEDResetPWR3.3 VID_UI
2-24 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualPower ButtonBlue+ (OH/Fan Fail/PWR FaiL/UID LED)1NIC1 Link LEDReset Button2Power Fail LED
Chapter 2: Installation2-25Power ButtonBlue+ (OH/Fan Fail/PWR FaiL/UID LED)1NIC1 Link LEDReset Button2Power Fail LEDHDD LEDFP PWRLEDResetPWR3.3 VID_UI
PrefacevContacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408) 503-8000Fax: +1 (40
2-26 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualPower Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily c
Chapter 2: Installation2-27Warning: To ensure adequate power supply to your motherboard, be sure to connect all the power connectors mentioned above t
2-28 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualChassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard. Attach
Chapter 2: Installation2-29A. TPM/Port 80 HeaderB. JOH1TPM Header/Port 80Trusted Platform Module/Port 80 header, located at JTPM1, provides TPM suppor
2-30 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualPower SMB (I2C) ConnectorsPower System Management Bus (I2C) Connectors (JI2C1/JI2C2) moni
Chapter 2: Installation2-312-8 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can be used to choose betwe
2-32 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualCMOS ClearJBT1 is used to clear CMOS. Instead of pins, this "jumper" consists o
Chapter 2: Installation2-33A. VGA EnabledB. BMC EnabledVGA EnableJumper JPG1 allows the user to enable the onboard VGA connector. The default setting
2-34 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualManagement Engine (ME) Recovery Use Jumper JPME1 to select ME Firm-ware Recovery mode, wh
Chapter 2: Installation2-352-8 Onboard LED IndicatorsA. LAN1/2 LEDs(GLAN1/GLAN2: X9DRG-HF, TLAN1/TLAN2: X9DRG-HTF),B. IPMI LAN LEDsIPMI Dedicated LA
viTable of ContentsPrefaceChapter 1 Overview 1-1 Overview ...
2-36 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualOnboard Power LED An Onboard Power LED is located at LE1 on the motherboard. When this L
Chapter 2: Installation2-37Rear UID LED The rear UID LED is located at LE4 on the backplane. This LED is used in conjunc-tion with the rear UID switch
2-38 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualNote: For more information on SATA HostRAID conguration, please refer to the Intel SATA
3-1Chapter 3: TroubleshootingChapter 3 Troubleshooting 3-1 Troubleshooting ProceduresUse the following procedures to troubleshoot your system. If
3-2 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualNo Video1. If the power is on, but you have no video, remove all the add-on cards and cab
3-3Chapter 3: TroubleshootingMemory Errors When a No-Memory Beep Code is issued by the system, check the following:1. Make sure that the memory modul
3-4 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual4. System cooling: Check system cooling to make sure that all heatsink fans, and CPU/syst
3-5Chapter 3: Troubleshooting3-2 Technical Support ProceduresBefore contacting Technical Support, please take the following steps. Also, please note
3-6 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualProper Battery DisposalWarning: Please handle used batteries carefully. Do not damage the
3-7Chapter 3: Troubleshooting3-4 Frequently Asked QuestionsQuestion: What are the various types of memory that my motherboard can support?Answer: Th
viiTable of ContentsUniversal Serial Bus (USB) ... 2-19Video Connection ...
3-8 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual3-5 Returning Merchandise for ServiceA receipt or copy of your invoice marked with the d
Chapter 4: AMI BIOS4-1Chapter 4 BIOS 4-1 IntroductionThis chapter describes the AMI BIOS Setup utility for the X9DRG-HF/7TF. It also provides the
4-2 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualHowToChangetheCongurationDataThe conguration data that determines the system parame
Chapter 4: AMI BIOS4-3System Date/System TimeUse this option to change the system time and date. Highlight System Time or System Date using the arrow
4-4 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual4-3 AdvancedSetupCongurationsSelect the Advanced tab to access the following submenu
Chapter 4: AMI BIOS4-5Interrupt 19 CaptureInterrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled
4-6 X9DRG-HF/X9DRG-HTF Motherboard User’s Manual•CPU Stepping•Maximum CPU Speed•Minimum CPU Speed•Processor Cores•Intel HT (Hyper-Thr
Chapter 4: AMI BIOS4-7Active Processor CoresSet to Enabled to use a processor's second core and above. (Please refer to Intel's website for
4-8 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualIntel® Virtualization Technology (Available when supported by the CPU)Select Enabled to su
Chapter 4: AMI BIOS4-9CPU C6 Report (Available when Power Technology is set to Custom)Select Enabled to allow the BIOS to report the CPU C6 State (ACP
viiiChapter 3 Troubleshooting 3-1 Troubleshooting Procedures ... 3-13-2 Te
4-10 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualShort Duration Power LimitThis item displays the time period during which short duration
Chapter 4: AMI BIOS4-11CPU1 Slot 2 PCI-E 3.0 x16 OPROMThis feature allows the user to set the PCI-Exp bus speed for the slot specied above. The optio
4-12 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualDIMMCongurationThis section displays the following DIMM information.Current Memory Mod
Chapter 4: AMI BIOS4-13Channel InterleavingThis feature selects from the different channel interleaving methods. The options are Auto, 1 Way, 2 Way, 3
4-14 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualSouthBridgeCongurationThis feature allows the user to congure the settings for the I
Chapter 4: AMI BIOS4-15SATA ModeUse this feature to congure SATA mode for a selected SATA port. The options are Disabled, IDE Mode, AHCI Mode and RAI
4-16 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualSCU(StorageControlUnit)CongurationStorage Controller UnitSelect Enabled to enable P
Chapter 4: AMI BIOS4-17Maximum Read RequestSelect Auto to allow the system BIOS to automatically set the maximum Read Request size for a PCI-E device
4-18 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualSuperIOCongurationSuper IO Chip: This item displays the Super IO chip used in the mot
Chapter 4: AMI BIOS4-19Device ModeUse this feature to select the desired mode for a serial port specied. The options are Normal and High Speed.Seria
Chapter 1: Overview1-1Note: For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user&a
4-20 X9DRG-HF/X9DRG-HTF Motherboard User’s Manualis odd. Select None if you do not want to send a parity bit with your data bits in transm
Chapter 4: AMI BIOS4-21Console RedirectionSelect Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and D
4-22 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualACPI Sleep StateUse this feature to select the ACPI State when the system is in sleep mod
Chapter 4: AMI BIOS4-23TPM Active StatusThis item displays the status of TPM Support to indicate if TPM is currently ac-tive or deactivated.TPM Owner
4-24 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualiSCSIConguration: This item displays iSCSI conguration information:iSCSI Initiator Nam
Chapter 4: AMI BIOS4-25•Chip Type•PCI Device ID•PCI Bus:Device:Function•Link Status•Factory MAC Address•Alternate MAC Address4-4 Event LogsSel
4-26 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualRuntime Error Logging SupportSelect Enabled to support Runtime Error Logging. The options
Chapter 4: AMI BIOS4-27View System Event LogThis item allows the user to view the event in the system event log. Select this item and press <Enter&
4-28 X9DRG-HF/X9DRG-HTF Motherboard User’s ManualErasing SettingsErase SELSelect Yes, On next reset to erase all system event logs upon ne
Chapter 4: AMI BIOS4-29Subnet MaskThis item displays the sub-network that this computer belongs to. The value of each three-digit number separated by
Comentários a estes Manuais